Features
Γ-DⅡ (Gamma -DⅡ) Has a Wide Range of Size Measuring
The Γ-DⅡ reduces the setting time for size changing.
Setting for size changing in the same workpiece does not need.
High Accuracy & Repeatability
High precision and minimization of thermal effect on measurement have been achieved by using optical scale system in the Γ-DⅡ .
The repeatability of Γ-DⅡ is less than or equal to 0.2 μm (the mean value obtained by measurement 25 times ± 4 σ ).
Accurate and Stable Measurement with High Responsiveness
The Γ-DⅡ function that follows the fluctuations of measuring-value has been improved.
IIt enables accurate and stable measurement with less error-occurring .
Compact Design and Slim Cable
The Γ-DⅡ is compact; essential functions are all in its body. And it does not need any relay boxes. The Γ-DⅡ also uses a slim cable, so it is easy to arrange the cable in building
the system which even has a narrow space, etc.
Application
・Measuring Inner diameter, Outer Diameter, Eccentricity and Difference in Level, etc.
Specifications
Model | Γ-DⅡ | |
---|---|---|
Product code | 0966100 | |
Standard finger length | 82 mm | 152 mm |
Repeatability | ≦ 0.2 µm (4 σ) | ≦ 0.4 µm (4 σ) |
Wide linear range (Reference value) |
≦0.05% / F.S. (12.5 mm range: ≦6.3 μm) |
≦0.05% / F.S. (20 mm range: ≦10 μm) |
Narrow linear range (Reference value) |
≦ 0.5%(≦ 5 μm)/ ± 500 μm | |
Measuring force (Downward) | 1.4 to 3.6 N | 0.8 to 2.2 N |
Measuring range | 12.5 (± 6.25) mm | 20 (± 10) mm |
Pre travel | 6.35 to 6.7 mm | 10.2 to 10.85 mm |
Retract stroke | 6.5 to 7 mm | 10.5 to 11.35 mm |
Retract system (Air pressure supply) |
Single-acting air cylinder (0.35 MPa to 0.5 MPa) | |
Waterproof standard | IP67 compliant | |
Diameter and length of the cable | φ 5.6 mm, 6 m | |
Weight (Body) | Approx. 0.8 kg |