PULCOM V4, V4S-025
Features
Higher Functionality
A higher level of functionality enables utilization of a wider range of applications.
・Measurement of two items:
Sizing + end face, sizing + post measurement and various other variations are available.
・P memory function:
Measurement of even or odd number of teeth on notched workpieces.
・P memory function:
Suitable for dynamic measuring after work on surface grinders
・BCD/BIN output function:
U1000A compliant data can be output by adding an I/O2 circuit board.
Easy Operation
LCD can display alphanumeric characters
・Interactive operation for a wide variety of settings.
・Measured and offset values can easily be checked on the LCD.
Same type of rotary switch as on U600 (previous unit), V7 and V8
・Rotary switch enables intuitive operation.
・Frequently used operations can be quickly selected.
・Unifying operation system with U600, V7 and V8 minimizes operator load when the control unit is changed.
DSP + RISC CPU Provide High Speed and Performance
The adoption of a DSP (digital signal processor) facilitates digital
processing of various signals at high speeds.
・In addition to a smoothing filter, the unit has a standard 7-step LPF
(low pass filter) selection function.
・Real-time processing of notch processes.
Superior Ease of Maintenance
Simplified I/O Monitor
・Wiring with machine can be easily checked.
Self-Diagnostic Program
・Interactive verifications enable user to perform primary maintenance.
Upper Level Compatibility with U400
・The U400 can be replaced by using an optional I/O cable.
Detachable Front Panel (V4S-025)
・The front panel is detachable so you can position it so it is easy for the
operator to use. The control board is built-in to the main unit. The panel
can be located a maximum of 10 meters away from the main unit.
V4B Overview
Specifications
Model | E-PV41□ | E-PV42□ | E-pv42□-S | |
---|---|---|---|---|
Number of detector inputs | 1 | 2 (1 input possible) | 2 (1 input possible) | |
Number of measuring items | 1 (2 optional) | |||
Judgment output | Max. 6 (1 measuring item), Max. 9 (2 measuring items) | |||
Display | Indicator + LCD character display | |||
Main functions |
Auto master set | Option | ||
Zero shift | Option | |||
Offset compensation | Immediate offset function (external offset is optional) | |||
Memory | Optional (max., min., P-P, integration memory, etc.) W standard | |||
Data output | Optional (BCD/BIN output, O.C., O.E. and O.D.) | |||
Dimension error detection | Option | |||
Workpiece pass verification | Optional (valid when memory function is provided) | |||
Run signal output | Option | |||
Analog output | Option | |||
2-item measurement | Option | |||
Power source | AC 85 – 250 V, 30 VA | |||
Waterproof standard | IP54 | IP54 (panel only) | ||
Detachable monitor | - | Special cable connection (standard: 5m, OP maximum 10m) | ||
Weight (Body) | Approx. 3.7 kg | Approx. 3.7 kg (Panel: Approx. 1.1 kg) |